Videotec MHX2CW0B0A Maximus MHX Stainless Steel Ex-Proof Camera

OR

Quick Overview

MHX AISI 316L housing 24Vac, camera Day/Night 10x PAL, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
Model Number: Videotec MHX2CW0B0A

Share This Page
Find us on Facebook space Follow us on Twitter space Add us on LinkedIn

Videotec MHX2CW0B0A Maximus MHX Stainless Steel Ex-Proof Camera

Double click on above image to view full picture

Zoom Out
Zoom In

More Views

  • 'More Views

Details

Videotec Video Systems Products


Videotec Maximus MHX Stainless Steel Ex-Proof Camera



Maximus MHX Key Features


• Made of AISI 316L electropolished stainless steel
• Integrated Day/Night camera 10x, 1/3"
• 2 ¾” NPT threaded holes for use of cable glands or conduit
• Integrated telemetry receiver for version with wiper
• Sunshield and heater included
• IP66/IP67



Maximus MHX Description


These explosion-proof cameras of MAXIMUS series have been certified and designed to meet the strictest standards regarding installation in potentially explosive environments, given the presence of gas and flammable dusts.


The MAXIMUS range ensures excellent performance for monitoring critical processes in areas with risk of explosion, such as refineries, gas pipelines, oil tankers, offshore platforms, industrial processes, chemical industries, etc. Equipped with heating, the housing has the same installation and operating temperatures, comprised between -40° C and + 60° (-40°F / +140°F).


In the version with wiper, MHX is equipped with an integrated telemetry receiver that allows, through the RS485 serial interface, to receive data from the remote control for the activation of the wiper / washer and for switching an eventual external illuminator (or controlled from the Day \ Night camera switch).


The wiring is made easier thanks to the removable connectors on the circuit board. The control board, with removable connectors, is also equipped with an input for the wiper activation through a dry contact.


The housing can eventually be controlled by VMS through a video encoder with RS485 serial port.

 

Maximus MHX Ordering Information

Product Code Description
MHX1CS000A MHX AISI 316L housing 230Vac, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX1CW000A MHX AISI 316L housing 230Vac, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX1CW0B0A MHX AISI 316L housing 230Vac, camera Day/Night 10x PAL, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX1CW0K0A MHX AISI 316L housing 230Vac, camera Day/Night 10x NTSC, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX2CS000A MHX AISI 316L housing 24Vac, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX2CW000A MHX AISI 316L housing 24Vac, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX2CW0B0A MHX AISI 316L housing 24Vac, camera Day/Night 10x PAL, wiper, sunshield.  ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX2CW0B0A-U MHX AISI 316L housing 24Vac, camera Day/Night 10x PAL, wiper, sunshield. USL – NORTH AMERICA Class I, Zone 1, AEx d IIC T6, Zone 21, AEx tb IIIC T85°C. CNL – CANADA Class I, Zone 1, Ex d IIC T6 Gb, Class II, Groups E, F and G
MHX2CW0K0A MHX AISI 316L housing 24Vac, camera Day/Night 10x NTSC, wiper, sunshield. ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX2CW0K0A-U MHX AISI 316L housing 24Vac, camera Day/Night 10x NTSC, wiper, sunshield. USL – NORTH AMERICA Class I, Zone 1, AEx d IIC T6, Zone 21, AEx tb IIIC T85°C. CNL – CANADA Class I, Zone 1, Ex d IIC T6 Gb, Class II, Groups E, F and G
MHX3CS000A MHX AISI 316L housing 120Vac, sunshield.  ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX3CW000A MHX AISI 316L housing 120Vac, wiper, sunshield.  ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db
MHX3CW0K0A MHX AISI 316L housing 120Vac, camera Day/Night 10x NTSC, wiper, sunshield.  ATEX Ex II 2 G Ex d IIC T6 Gb Ta -40°C to +60°C Ex II 2 D Ex tb IIIC T85°C Db Ta -40°C to +60°C. IECEx Ex d IIC T6 Gb Ta -40°C to +60°C Ex tb IIIC T85°C Db Ta -40°C to +60°C. INMETRO Ex d IIC T6 Gb Ex tb IIIC T85°C Db Tamb -40°C to +60°C. EAC Ex d IIC T6 Gb, Ex tb IIIC T85 Db